Tests:Digoxin, Plasma: Difference between revisions

Tests:Digoxin, Plasma
Created page with "{{DISPLAYTITLE: Digoxin, Plasma}} Full Test List Biochemistry Tests {| class="wikitable" ! colspan="2" | ===''Overview''=== |- |Department |Biochemistry |- |Test Code |DIG |- |Synonyms |Digitalis  |- |Turnaround Time |1 – 5hrs  |- |Stability – Add test |8 hours |- ! colspan="2" | ===''Specimen Requirements''=== |- |Specimen Type |Serum Plasma |- |Specimen Transportation | |- |Preferred |6 mL <span style="background:#e30022"> Red-Top</span> |- |Accepta..."
 
Updated method Alinity
 
(4 intermediate revisions by 3 users not shown)
Line 4: Line 4:
{| class="wikitable"
{| class="wikitable"
! colspan="2" |
! colspan="2" |
===''Overview''===
== Overview ==
|-
|-
|Department
|Department
Line 14: Line 14:
|Synonyms
|Synonyms
|Digitalis 
|Digitalis 
|-
|Availability
|Monday - Sunday, testing routinely available out of hours
|-
|-
|Turnaround Time
|Turnaround Time
Line 22: Line 25:
|-
|-
! colspan="2" |
! colspan="2" |
===''Specimen Requirements''===
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen  
|Serum
|Serum


Plasma
Plasma
|-
|Specimen Transportation
|
|-
|-
|Preferred
|Preferred
Line 38: Line 38:
|6 mL Li-Hep <span style="background:#3cb371"> Green-Top </span>
|6 mL Li-Hep <span style="background:#3cb371"> Green-Top </span>
|-
|-
|Pediatric Requirements
|Unacceptable
|<span style="background:#99e6b3"> Li-Hep Microtainer </span>
|
|-
|Specimen Transportation
|
|-
|Paediatric Requirements
|<span style="background:#99e6b3"> Li-Heparin Microtainer </span>
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Aliquot Requirements'' ===
== Aliquot Requirements ==
|-
|-
|Sample Type
|Sample  
|Serum
|Serum
Plasma
Plasma
|-
|Preferred Volume
|500 µL 
|-
|-
|Minimum Volume
|Minimum Volume
Line 55: Line 64:
|-
|-
! colspan="2" |
! colspan="2" |
===''Clinical Information''===
== Clinical Information ==
|-
|-
|Reference Intervals
|Reference Intervals
Line 63: Line 72:
|-
|-
|Test Method
|Test Method
|Abbott Alinity Ci, Particle-enhanced turbidimetric inhibition immunoassay (PETINIA) 
|Abbott Alinity c series analyser using Abbott reagents. Particle-enhanced turbidimetric inhibition immunoassay (PETINIA) 
|-
|-
|Advanced Notice
|Advanced Notice
Line 72: Line 81:
|-
|-
! colspan="2" |
! colspan="2" |
===''Comments''===
== Comments ==
|-
|-
| colspan="2" |Specimens from patients treated with Digoxin immune FAB (Digibind) should be viewed with caution, as this substance is known to inhibit the assay.  
| colspan="2" |Specimens from patients treated with Digoxin immune FAB (Digibind) should be viewed with caution, as this substance is known to inhibit the assay causing false elevated values.  


Heterophilic antibodies have been shown to interact with immunoglobulin reagents in some immunoassay systems.   
Heterophilic antibodies have been shown to interact with immunoglobulin reagents in some immunoassay systems.   
|}
|}
{{DocMeta
| owner = Crossley1
| review_ping =
}}