Tests:Hepatitis C Serology: Difference between revisions

Tests:Hepatitis C Serology
No edit summary
Updated method Alinity
 
(7 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{DISPLAYTITLE: Hepatitis C Serology}}  
{{DISPLAYTITLE: Hepatitis C Serology}}
{{DEFAULTSORT: Hepatitis C Serology}}
[[Category:Tests]]
[[Category:Tests]]
[[Category:Biochemistry]]  
[[Category:Biochemistry]]  
{| class="wikitable"
{| class="wikitable"
! colspan="2" |
! colspan="2" |
=== ''Overview'' ===
== Overview ==
|-
|-
|Department
|Department
Line 14: Line 15:
|Synonyms
|Synonyms
|Anti HCV serology   
|Anti HCV serology   
|-
|Availability
|Monday, Wednesday, and Friday afternoons
Urgent testing available by arrangement
|-
|-
|Turnaround Time
|Turnaround Time
|1 – 3 days
|1 – 4 days
|-
|-
|Stability – Add test
|Stability – Add test
Line 22: Line 27:
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Specimen Requirements'' ===
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen  
|Serum
|Serum or LiHep Plasma
|-
|Specimen Transportation
|
|-
|-
|Preferred
|Preferred
|6 mL plain <span style="background:#e30022"> Red-Top</span>
|<span style="background: #fbec5d"> Yellow-Top</span> serum separator tube
|-
|-
|Acceptable
|Acceptable
|4 mL Li-Heparin <span style="background:#3cb371"> Green-Top </span>, or 6 mL <span style="background: #fbec5d"> Yellow-Top</span> serum separator tube. 
|Plain <span style="background:#e30022"> Red-Top</span> or Li-Heparin <span style="background:#3cb371"> Green-Top </span> tube  
|-
|Unacceptable
|EDTA plasma
|-
|-
|Pediatric Requirements   
|Specimen Transportation
|2 mL in plain <span style="background:#e30022"> Red-Top</span> or Li-Heparin <span style="background:#3cb371"> Green-Top </span>   tube 
|
|-
|Paediatric Requirements   
|2 mL plain adult <span style="background:#e30022"> Red-Top</span> or <span style="background:#3cb371"> Green-Top </span>   
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Aliquot Requirements'' ===
== Aliquot Requirements ==
|-
|-
|Sample Type
|Sample  
|
|Serum or LiHep Plasma
|-
|Preferred Volume
|1 mL
|-
|-
|Minimum Volume
|Minimum Volume
Line 52: Line 63:
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Clinical Information'' ===
== Clinical Information ==
|-
|-
|Reference Intervals
|Reference Intervals
Line 58: Line 69:
|-
|-
|Test Method
|Test Method
|Ci8200 analyser, Abbott Reagents.  CMIA method. 
|Abbott Alinity i series analyser using Abbott reagents.  Chemiluminescent microparticle immunoassay.  
|-
|-
|Advanced Notice
|Advanced Notice
Line 67: Line 78:
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Comments'' ===
== Comments ==
|-
|-
| colspan="2" |Where needlestick or similar injury involved, refer to protocol in Infection Control Manual, “Blood Borne Pathogen Response – Needle Stick Injury Protocol.”   
| colspan="2" |Where needlestick or similar injury involved, refer to protocol in Infection Control Manual, “Blood Borne Pathogen Response – Needle Stick Injury Protocol.”   
|}
|}
{{DocMeta
| owner = Crossley1
| review_ping =
}}