Tests:Lactate, Blood: Difference between revisions

Tests:Lactate, Blood
Created page with "{{DISPLAYTITLE: Lactate, Blood}} Full Test List Biochemistry Tests {| class="wikitable" ! colspan="2" | === ''Overview'' === |- |Department |Biochemistry  |- |Test Code |TLAC |- |Synonyms |Lactic Acid  |- |Turnaround Time |15 – 60 minutes  |- |Stability – Add test | |- ! colspan="2" | === ''Specimen Requirements'' === |- |Specimen Type |Plasma |- |Specimen Transportation |Send to Lab ASAP  |- |Preferred |1 mL heparin blood gas syringe |- |Accept..."
 
No edit summary
 
(8 intermediate revisions by 3 users not shown)
Line 2: Line 2:
[[Category:Tests]]
[[Category:Tests]]
[[Category:Biochemistry]]  
[[Category:Biochemistry]]  
[[Category:Hawera]]
{| class="wikitable"
{| class="wikitable"
! colspan="2" |
! colspan="2" |
=== ''Overview'' ===
== Overview ==
|-
|-
|Department
|Department
Line 14: Line 16:
|Synonyms
|Synonyms
|Lactic Acid   
|Lactic Acid   
|-
|Base Lab Availability
|Monday - Sunday, testing routinely available out of hours
|-
|Hawera Lab Availability
|Monday - Friday, 8am to 4 30pm
|-
|-
|Turnaround Time
|Turnaround Time
|15 – 60 minutes   
|15 – 30 minutes   
|-
|-
|Stability – Add test
|Stability – Add test
|
|Not available
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Specimen Requirements'' ===
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen  
|Plasma
|Whole Blood
|-
|Specimen Transportation
|Send to Lab ASAP 
|-
|-
|Preferred
|Preferred
|1 mL heparin blood gas syringe  
|1 mL heparin blood gas syringe, mix well
|-
|-
|Acceptable
|Acceptable
|4 mL <span style="background:#3cb371"> Green-Top </span>   Li-Hep, mix well    
|4 mL Li-Hep <span style="background:#3cb371"> Green-Top </span>, mix well    
|-
|Unacceptable
|Samples with needle attached
samples older than 30 minutes
|-
|Specimen Transportation
|Send to Lab ASAP 
|-
|-
|Pediatric  Requirements   
|Paediatric Requirements   
|0.3 mL small blood gas syringe, or 600 μL Li-Hep microtainer tube. Mix well    
|0.3 mL small blood gas syringe, or 600 μL <span style="background:#99e6b3"> Li-Hep Microtainer, </span>Mix well    
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Aliquot Requirements'' ===
== Aliquot Requirements ==
|-
|-
|Sample Type
|Sample  
|
|-
|Preferred Volume
|
|
|-
|-
Line 52: Line 67:
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Clinical Information'' ===
== Clinical Information ==
|-
|-
|Reference Intervals
|Reference Intervals
Line 58: Line 73:
|-
|-
|Test Method
|Test Method
|Base : Radiometer ABL90 FLEX Blood gas analyser  
|Radiometer ABL90 FLEX/FLEX plus Blood gas analyser
 
Hawera : iSTAT 1 CG4+  Cartridge
|-
|-
|Advanced Notice
|Advanced Notice
Line 69: Line 82:
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Comments'' ===
== Comments ==
|-
|-
| colspan="2" |Lactate results are higher in venous blood than arterial blood.     
| colspan="2" |Lactate results are higher in venous blood than arterial blood.     
Line 75: Line 88:
Blood gases and electrolytes can be measured on the same blood gas syringe sample.   
Blood gases and electrolytes can be measured on the same blood gas syringe sample.   
|}
|}
{{DocMeta
| owner = Crossley1
| review_ping =
}}