Tests:Bilirubin Conjugated Direct, Plasma: Difference between revisions
Tests:Bilirubin Conjugated Direct, Plasma
No edit summary |
No edit summary |
||
| Line 14: | Line 14: | ||
|- | |- | ||
|Synonyms | |Synonyms | ||
|Conjugated | |Conjugated | ||
Direct | |||
Direct | CBil | ||
CBil | |||
DBil | DBil | ||
|- | |- | ||
| Line 32: | Line 29: | ||
|- | |- | ||
|Specimen Type | |Specimen Type | ||
|7 mL Plain <span style="background:#e30022"> | |Plasma | ||
Serum | |||
|- | |||
|Preferred | |||
|7 mL Plain <span style="background:#e30022"> Red-Top </span> | |||
|- | |||
|Acceptable | |||
|7 mL <span style="background:#ffd700"> Gold-Top </span> or 5 mL Li-Hep <span style="background:#3cb371"> Green-Top </span> | |||
|- | |- | ||
|Specimen Transportation | |Specimen Transportation | ||
| Line 41: | Line 45: | ||
|- | |- | ||
|Pediatric Requirements | |Pediatric Requirements | ||
|<span style="background:#99e6b3"> Li Hep Microtainer </span> | |600 µl <span style="background:#99e6b3"> Li Hep Microtainer </span> Paediatric tube | ||
|- | |- | ||
! colspan="2" | | ! colspan="2" | | ||
| Line 47: | Line 51: | ||
|- | |- | ||
|Sample Type | |Sample Type | ||
| | |Plasma | ||
Serum | |||
|- | |- | ||
|Minimum Volume | |Minimum Volume | ||
Revision as of 10:23, 31 January 2025
Overview | |
|---|---|
| Department | Biochemistry |
| Test Code | PBTD |
| Synonyms | Conjugated
Direct CBil DBil |
| Turnaround Time | 1 hour urgent, 2 hours routine |
| Stability – Add test | |
Specimen Requirements | |
| Specimen Type | Plasma
Serum |
| Preferred | 7 mL Plain Red-Top |
| Acceptable | 7 mL Gold-Top or 5 mL Li-Hep Green-Top |
| Specimen Transportation | Protect from light were possible. |
| Preferred | |
| Pediatric Requirements | 600 µl Li Hep Microtainer Paediatric tube |
Aliquot Requirements | |
| Sample Type | Plasma
Serum |
| Minimum Volume | 100 µL |
| Aliquot Transportation | |
Clinical Information | |
| Reference Intervals | Reference range 0 - 5 umol/L |
| Test Method | Colourimetric reaction based on Jendrassik & Grof, Abbott ci8200 analyser, Abbott Reagents. |
| Advanced Notice | Not Required |
| Patient Preparation | Not Required |
Comments | |
| Bilirubin is destroyed by light | |