Tests:HbA1c (POCT): Difference between revisions

Tests:HbA1c (POCT)
Pam Chung (talk | contribs)
No edit summary
Pam Chung (talk | contribs)
No edit summary
Line 14: Line 14:
|'''Synonyms'''
|'''Synonyms'''
|HbA1c whole blood (POCT)
|HbA1c whole blood (POCT)
glycated haemoglobin
HBA
|-
|-
|'''Availability'''
|'''Availability'''
|Cobas b101 HbA1c devices are available at both Taranaki Base and Hawera hospital.
|Cobas b101 HbA1c devices are available at both Taranaki Base and Hawera hospital.
The Ketone meters <u>must</u> be returned to the Laboratory after use for others to use and QC.
|-
|-
|'''Turnaround Time'''
|'''Turnaround Time'''
|As and when the Ketone meters are available.
|6 minutes from placing cartridge into analyser with patients' blood sample
Results once tested - 10 seconds
|-
|-
|'''Stability – Add test'''
|'''Stability – Add test'''
|N/A
|60 seconds once blood sample has been applied to cartridge disc.
EDTA samples within 2 hours from collection
Lithium-Heparin within 8 hours from collection
|-
|-
! colspan="2" |
! colspan="2" |
Line 36: Line 38:
|-
|-
|'''Acceptable'''
|'''Acceptable'''
|Blood Gas, Purple top (EDTA), 0.6 µL capillary sample collected directly onto a Statstrip test strip
|Purple top (EDTA) or Lithium-Heparin, non-gel (green top)
|-
|-
|'''Unacceptable'''
|'''Unacceptable'''
|Samples older than 4 hours
|Samples containing anticoagulants or other additives
Neonate samples
 
Separated samples
Separated samples
|-
|-
|'''Minimum Volume'''
|'''Minimum Volume'''
|0.6 µL whole blood
|2µL whole blood
|-
|-
|'''Specimen Collection and Transportation'''
|'''Specimen Collection and Transportation'''
Line 54: Line 54:
|-
|-
|'''Test Method'''
|'''Test Method'''
|Nova StatStrip Xpress 1/2 handheld device and Ketone StatStrip
|Cobas b101 - ROCHE analyser
|-
|-
|'''Unit of Measurement'''
|'''Unit of Measurement'''
| mmol/L
| mmol/mol
|-
|-
|'''Reference Intervals'''
|'''Reference Intervals'''
|<0.3 mmol/L
|Non-diabetic reference interval 20-40 mmol/mol.
Risk of microvascular complications increases exponentially above 55 mmol/mol.
 
If >/= 50 mmol/mol and not known to have diabetes, a repeat level >/= 50 after an interval supports the diagnosis.
 
If result is >65 mmol/mol, consider additional action.
|-
|-
|'''Uncertainty of measurement'''
|'''Uncertainty of measurement'''
Line 66: Line 71:
|-
|-
|'''Additional Information'''
|'''Additional Information'''
|Ketones include acetoacetic acid, beta-hydroxybutyric acid and acetone. The relative proportions of all ketones depend on the severity of the ketosis and the availability of NADH for metabolism. Beta-hydroxybutyric acid (OHB) can be added up to 4 hrs pos.
|Ranges of measurement 20-130mmol/mol
Ketone Measuring range 0.1 -7.0mmol/L
The presence of some haemoglobin variants may require testing via alternative methods for HbA1c or the laboratory may refer clinician to glucose based criteria for diagnosis and monitoring.
|-
|-
! colspan="2" |
! colspan="2" |
== '''Comments''' ==
== '''Comments''' ==
|-
|-
| colspan="2" |Quick user guides for testing should be available with the meter.
| colspan="2" |Quick user guides for testing should be available with or near the analysers.
All procedures, worksheets and competency checklist for sig off are available to all Health NZ Staff.
All procedures, worksheets and competency checklist for sign-off are available on the intranet to all Health NZ Staff.
|}
|}
{{DocMeta