Fibrinogen, Plasma


Tests:Fibrinogen, Plasma

Overview

Department Haematology    
Test Code FIB
Synonyms Coag screen

DIC screen  

Test Availability Monday - Sunday, testing routinely available out of hours
Turnaround Time 1 – 4 hrs    
Stability – Add test   24 hrs

Specimen Requirements

Specimen Type Plasma
Preferred 2.7 mL na citrate Blue-Top
Acceptable
Unacceptable Clotted samples

Under or overfilled tubes Haemolysed Samples older than 24 hours

Specimen Transportation Ambient  
Paediatric Requirements   1.0 mL Blue-Top    

Aliquot Requirements

Sample Type
Preferred Volume
Minimum Volume
Aliquot Transportation

Clinical Information

Reference Intervals Reference Range  1.5 - 4.0 g/L  
Test Method Von Clauss method using mechanical clot detection, performed on Stago Compact Max2 Analyser  
Advanced Notice Not required    
Patient Preparation Not required    

Comments

Included in coagulation screen.  

Cryoprecipitate transfusion is indicated if fibrinogen is <1.0 g/L in the presence of clinical bleeding.