Haemoglobin Profile, Blood
Tests:Haemoglobin Profile, Blood
Overview | |
|---|---|
| Department | Biochemistry |
| Test Code | |
| Synonyms | tHb
CarboxyHb MetHb |
| Turnaround Time | 30 minutes |
| Stability – Add test | |
Specimen Requirements | |
| Specimen Type | Blood |
| Specimen Transportation | Ambient to laboratory if less than 30 minutes otherwise on ice for up to 1 hour. |
| Preferred | 1mL heparinised gas syringe |
| Acceptable | 4 mL Heparin Green-Top must be completely full, mix well |
| Paediatric Requirements | 0.2mL in Paediatric heparinised blood gas syringe. |
Aliquot Requirements | |
| Sample Type | |
| Minimum Volume | 0.3mL in heparinised syringe. |
| Aliquot Transportation | |
Clinical Information | |
| Reference Intervals | Reference Ranges:
Oxyhaemoglobin: 94-97% Carboxyhaemoglobin: 0.0-1.5% Methaemoglobin: 0.0-1.5% Reduced Haemoglobin: 0.0-5.0%
Blood gases and electrolytes can be measured on the same sample. (Potassium will not be available if sample has been on ice, full blood gas only available if in blood gas syringe)
Carboxyhaemoglobin level higher in smokers (up to 9%). |
| Test Method | Radiometer ABL90 FLEX blood gas analyser. |
| Advanced Notice | Not required |
| Patient Preparation | Not required |
Comments | |