Tests:Fibrinogen, Plasma: Difference between revisions
- Department
- Haematology
Tests:Fibrinogen, Plasma
No edit summary |
m Bulk update DocMeta owner to Mabbett1 |
||
| (One intermediate revision by one other user not shown) | |||
| Line 20: | Line 20: | ||
DIC screen | DIC screen | ||
|- | |- | ||
|Availability | |Base Lab Availability | ||
|Monday - Sunday, testing routinely available out of hours | |Monday - Sunday, testing routinely available out of hours | ||
|- | |||
|Hawera Lab Availability | |||
|Monday - Friday 8 am - 5pm | |||
|- | |- | ||
|Turnaround Time | |Turnaround Time | ||
| Line 88: | Line 91: | ||
| colspan="2" | Cryoprecipitate transfusion is indicated if fibrinogen is <1.0 g/L in the presence of clinical bleeding. | | colspan="2" | Cryoprecipitate transfusion is indicated if fibrinogen is <1.0 g/L in the presence of clinical bleeding. | ||
|} | |} | ||
{{DocMeta | |||
| owner = Mabbett1 | |||
| review_ping = | |||
}} | |||
Latest revision as of 13:11, 12 September 2025
Included in coagulation screen
Overview | |
|---|---|
| Department | Haematology |
| Test Code | FIB |
| Synonyms | Coag screen
DIC screen |
| Base Lab Availability | Monday - Sunday, testing routinely available out of hours |
| Hawera Lab Availability | Monday - Friday 8 am - 5pm |
| Turnaround Time | 1 – 4 hrs |
| Stability – Add test | 24 hrs |
Specimen Requirements | |
| Specimen | Plasma |
| Preferred | 2.7 mL na citrate Blue-Top |
| Acceptable | |
| Unacceptable | Clotted samples
Under or overfilled tubes Haemolysed Samples older than 24 hours |
| Specimen Transportation | Ambient |
| Paediatric Requirements | 1.0 mL Blue-Top |
Aliquot Requirements | |
| Sample | |
| Preferred Volume | |
| Minimum Volume | |
| Aliquot Transportation | |
Clinical Information | |
| Reference Intervals | Reference Range 1.5 - 4.0 g/L |
| Test Method | Von Clauss method using mechanical clot detection, performed on Stago Compact Max2 Analyser |
| Advanced Notice | Not required |
| Patient Preparation | Not required |
Comments | |
| Cryoprecipitate transfusion is indicated if fibrinogen is <1.0 g/L in the presence of clinical bleeding. | |
| Owner | Craig Mabbett (Mabbett1) |
|---|---|
| Last reviewed | 12 Sep 2025 |
| Next review | Overdue, 12 Sep 2026 |