Created page with "{{DISPLAYTITLE: Lactate, Blood}} Full Test List Biochemistry Tests {| class="wikitable" ! colspan="2" | === ''Overview'' === |- |Department |Biochemistry  |- |Test Code |TLAC |- |Synonyms |Lactic Acid  |- |Turnaround Time |15 – 60 minutes  |- |Stability – Add test | |- ! colspan="2" | === ''Specimen Requirements'' === |- |Specimen Type |Plasma |- |Specimen Transportation |Send to Lab ASAP  |- |Preferred |1 mL heparin blood gas syringe |- |Accept..."
 
No edit summary
 
(8 intermediate revisions by 3 users not shown)
Line 2: Line 2:
[[Category:Tests]]
[[Category:Tests]]
[[Category:Biochemistry]]  
[[Category:Biochemistry]]  
[[Category:Hawera]]
{| class="wikitable"
{| class="wikitable"
! colspan="2" |
! colspan="2" |
=== ''Overview'' ===
== Overview ==
|-
|-
|Department
|Department
Line 14: Line 16:
|Synonyms
|Synonyms
|Lactic Acid   
|Lactic Acid   
|-
|Base Lab Availability
|Monday - Sunday, testing routinely available out of hours
|-
|Hawera Lab Availability
|Monday - Friday, 8am to 4 30pm
|-
|-
|Turnaround Time
|Turnaround Time
|15 – 60 minutes   
|15 – 30 minutes   
|-
|-
|Stability – Add test
|Stability – Add test
|
|Not available
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Specimen Requirements'' ===
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen  
|Plasma
|Whole Blood
|-
|Specimen Transportation
|Send to Lab ASAP 
|-
|-
|Preferred
|Preferred
|1 mL heparin blood gas syringe  
|1 mL heparin blood gas syringe, mix well
|-
|-
|Acceptable
|Acceptable
|4 mL <span style="background:#3cb371"> Green-Top </span>   Li-Hep, mix well    
|4 mL Li-Hep <span style="background:#3cb371"> Green-Top </span>, mix well    
|-
|Unacceptable
|Samples with needle attached
samples older than 30 minutes
|-
|Specimen Transportation
|Send to Lab ASAP 
|-
|-
|Pediatric  Requirements   
|Paediatric Requirements   
|0.3 mL small blood gas syringe, or 600 μL Li-Hep microtainer tube. Mix well    
|0.3 mL small blood gas syringe, or 600 μL <span style="background:#99e6b3"> Li-Hep Microtainer, </span>Mix well    
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Aliquot Requirements'' ===
== Aliquot Requirements ==
|-
|-
|Sample Type
|Sample  
|
|-
|Preferred Volume
|
|
|-
|-
Line 52: Line 67:
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Clinical Information'' ===
== Clinical Information ==
|-
|-
|Reference Intervals
|Reference Intervals
Line 58: Line 73:
|-
|-
|Test Method
|Test Method
|Base : Radiometer ABL90 FLEX Blood gas analyser  
|Radiometer ABL90 FLEX/FLEX plus Blood gas analyser
 
Hawera : iSTAT 1 CG4+  Cartridge
|-
|-
|Advanced Notice
|Advanced Notice
Line 69: Line 82:
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Comments'' ===
== Comments ==
|-
|-
| colspan="2" |Lactate results are higher in venous blood than arterial blood.     
| colspan="2" |Lactate results are higher in venous blood than arterial blood.     
Line 75: Line 88:
Blood gases and electrolytes can be measured on the same blood gas syringe sample.   
Blood gases and electrolytes can be measured on the same blood gas syringe sample.   
|}
|}
{{DocMeta
| owner = Crossley1
| review_ping =
}}

Latest revision as of 09:43, 3 October 2025


Overview

Department Biochemistry 
Test Code TLAC
Synonyms Lactic Acid 
Base Lab Availability Monday - Sunday, testing routinely available out of hours
Hawera Lab Availability Monday - Friday, 8am to 4 30pm
Turnaround Time 15 – 30 minutes 
Stability – Add test Not available

Specimen Requirements

Specimen Whole Blood
Preferred 1 mL heparin blood gas syringe, mix well
Acceptable 4 mL Li-Hep Green-Top , mix well  
Unacceptable Samples with needle attached

samples older than 30 minutes

Specimen Transportation Send to Lab ASAP 
Paediatric Requirements  0.3 mL small blood gas syringe, or 600 μL Li-Hep Microtainer, Mix well  

Aliquot Requirements

Sample
Preferred Volume
Minimum Volume
Aliquot Transportation

Clinical Information

Reference Intervals 0.5 - 2.0 mmol/L (arterial)  
Test Method Radiometer ABL90 FLEX/FLEX plus Blood gas analyser
Advanced Notice
Patient Preparation

Comments

Lactate results are higher in venous blood than arterial blood.  

Blood gases and electrolytes can be measured on the same blood gas syringe sample. 

Owner Clair Crossley (Crossley1)
Last reviewed 3 Oct 2025
Next review Overdue, 3 Oct 2026