Jump to content
Health NZ Taranaki Lab Manual

Tests:CA 125: Difference between revisions

Department
Biochemistry
Tests:CA 125
No edit summary
No edit summary
 
(6 intermediate revisions by 4 users not shown)
Line 20: Line 20:
|-
|-
|Test Availability
|Test Availability
|Tuesday and Thursday
|Tested Monday, Wednesday and Friday afternoons.
Contact lab if testing is required urgently
Please contact the laboratory if testing is required urgently
|-
|-
|Turnaround Time
|Turnaround Time
Line 27: Line 27:
|-
|-
|Stability – Add test
|Stability – Add test
|
|24 hours
|-
|-
! colspan="2" |
! colspan="2" |
== Specimen Requirements ==
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen  
|Serum
|Serum
Plasma
|-
|Specimen Transportation
|
|-
|-
|Preferred
|Preferred
|7mL <span style="background:#e30022"> Red-Top </span>
|<span style="background: #fbec5d"> Yellow-Top</span> SST or <span style="background:#e30022"> Red-Top </span> tube
|-
|-
|Acceptable
|Acceptable
|SST <span style="background: #fbec5d"> Yellow-Top</span>
|
|-
|-
|Unacceptable
|Unacceptable
|Plasma
|-
|Specimen Transportation
|
|
|-
|-
|Paediatric Requirements
|Paediatric Requirements
|0.5 <span style="background:#e30022"> Red </span> microtainer  
|0.5 mL <span style="background:#e30022"> Red </span> microtainer  
|-
|-
! colspan="2" |
! colspan="2" |
== Aliquot Requirements ==
== Aliquot Requirements ==
|-
|-
|Sample Type
|Sample  
|Serum
|Serum
|-
|-
Line 73: Line 72:
|-
|-
|Test Method
|Test Method
|Abbott Architect analyser using Abbott reagents.    
|Abbott Alinity i series analyser using Abbott reagents.  Chemiluminescent microparticle immunoassay.
 
CMIA method
|-
|-
|Advanced Notice
|Advanced Notice
Line 90: Line 87:
For the serial monitoring of tumours, tumour markers should be tested in the same laboratory.
For the serial monitoring of tumours, tumour markers should be tested in the same laboratory.
|}
|}
{{DocMeta
| owner = Crossley1
| review_ping =
}}
<!-- review-ping: 2026-09-14T07:57:57.920Z -->

Latest revision as of 21:36, 23 September 2026


Overview

Department Biochemistry 
Test Code CA25
Synonyms C125

C-125

C12-5

Test Availability Tested Monday, Wednesday and Friday afternoons.

Please contact the laboratory if testing is required urgently

Turnaround Time 1 – 4 days 
Stability – Add test 24 hours

Specimen Requirements

Specimen Serum
Preferred Yellow-Top SST or Red-Top tube
Acceptable
Unacceptable Plasma
Specimen Transportation
Paediatric Requirements 0.5 mL Red microtainer  

Aliquot Requirements

Sample Serum
Preferred Volume >500 uL
Minimum Volume 200 uL
Aliquot Transportation Samples should be separated from red cells within 24hrs of collection. 

Clinical Information

Reference Intervals <35 U/mL 
Test Method Abbott Alinity i series analyser using Abbott reagents.  Chemiluminescent microparticle immunoassay.
Advanced Notice
Patient Preparation

Comments

Used for monitoring Ovarian Carcinoma.

For the serial monitoring of tumours, tumour markers should be tested in the same laboratory.

Owner Clair Crossley (Crossley1)
Last reviewed 23 Sep 2026
Next review 23 Sep 2027 OK