Jump to content
Health NZ Taranaki Lab Manual

Tests:Potassium, Plasma: Difference between revisions

Department
Biochemistry
Also at
Hawera
Tests:Potassium, Plasma
Created page with "{{DISPLAYTITLE: Potassium, Plasma}} Full Test List Biochemistry Tests {| class="wikitable" ! colspan="2" | === ''Overview'' === |- |Department |Biochemistry   |- |Test Code |PPOT |- |Synonyms |Electrolytes (includes Na)   Na & K   |- |Constituent Tests |Anion Gap Electrolytes |- |Turnaround Time |1 – 4hrs   |- |Stability – Add test |3 hrs |- ! colspan="2" | === ''Specimen Requirements'' === |- |Specimen Type |Plasma Serum |- |Specimen..."
 
No edit summary
 
(6 intermediate revisions by 3 users not shown)
Line 3: Line 3:
[[Category:Tests]]  
[[Category:Tests]]  


[[Category:Biochemistry]]
[[Category:Biochemistry]]
[[Category:Hawera]]
{| class="wikitable"
{| class="wikitable"
! colspan="2" |
! colspan="2" |
=== ''Overview'' ===
== Overview ==
|-
|-
|Department  
|Department  
Line 13: Line 14:
|Test Code  
|Test Code  
|PPOT
|PPOT
|-
|Constituent Tests
|Anion Gap
Electrolytes
|-
|-
|Synonyms  
|Synonyms  
Line 19: Line 24:
Na & K    
Na & K    
|-
|-
|Constituent Tests
|Base Lab Availability
|Anion Gap
|Monday - Sunday, testing routinely available out of hours
Electrolytes
|-
|Hawera Lab Availability
|Monday - Friday, 8am to 4 30pm
|-
|-
|Turnaround Time  
|Turnaround Time  
Line 30: Line 37:
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Specimen Requirements'' ===
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen  
|Plasma
|Plasma


Serum
Serum
|-
|Specimen Transportation
|
|-
|-
|Preferred  
|Preferred  
Line 46: Line 50:
|4 mL Li-Heparin <span style="background:#3cb371"> Green-Top </span>      
|4 mL Li-Heparin <span style="background:#3cb371"> Green-Top </span>      
|-
|-
|Pediatric Requirements    
|Unacceptable
|Moderately and grossly haemolysed samples
|-
|Specimen Transportation
|
|-
|Paediatric Requirements    
|600 µL <span style="background:#99e6b3"> Li-Hep Microtainer </span>    
|600 µL <span style="background:#99e6b3"> Li-Hep Microtainer </span>    
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Aliquot Requirements'' ===
== Aliquot Requirements ==
|-
|Sample
|
|-
|-
|Sample Type
|Preferred Volume
|
|
|-
|-
Line 62: Line 75:
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Clinical Information'' ===
== Clinical Information ==
|-
|-
|Reference Intervals  
|Reference Intervals  
Line 68: Line 81:
|-
|-
|Test Method  
|Test Method  
|Ion selective electrode (Indirect method) performed on the Abbott ci8200 analyser  
|Abbott Alinity c series analyser using Abbott reagents.  Indirect by Ion Selective Electrode.
|-
|-
|Advanced Notice  
|Advanced Notice  
Line 77: Line 90:
|-
|-
! colspan="2" |
! colspan="2" |
=== ''Comments'' ===
== Comments ==
|-
|-
| colspan="2" |Venostasis may cause up to 30% increase in 5 minutes.   
| colspan="2" |Venostasis may cause up to 30% increase in 5 minutes.   
Line 83: Line 96:
Haemolysis, prolonged standing of specimen and/or squeezing of heel or finger (adding tissue fluid to the sample) during paediatric collects with give elevated results.    
Haemolysis, prolonged standing of specimen and/or squeezing of heel or finger (adding tissue fluid to the sample) during paediatric collects with give elevated results.    
|}
|}
{{DocMeta
| owner = Crossley1
| review_ping =
}}

Latest revision as of 21:59, 23 September 2026

Overview

Department Biochemistry  
Test Code PPOT
Constituent Tests Anion Gap

Electrolytes

Synonyms Electrolytes (includes Na)  

Na & K  

Base Lab Availability Monday - Sunday, testing routinely available out of hours
Hawera Lab Availability Monday - Friday, 8am to 4 30pm
Turnaround Time 1 – 4hrs  
Stability – Add test 3 hrs

Specimen Requirements

Specimen Plasma

Serum

Preferred 6 mL Plain Red-Top
Acceptable 4 mL Li-Heparin Green-Top    
Unacceptable Moderately and grossly haemolysed samples
Specimen Transportation
Paediatric Requirements   600 µL Li-Hep Microtainer   

Aliquot Requirements

Sample
Preferred Volume
Minimum Volume
Aliquot Transportation

Clinical Information

Reference Intervals All ages: 3.5 - 5.2 mmol/L  
Test Method Abbott Alinity c series analyser using Abbott reagents.  Indirect by Ion Selective Electrode.
Advanced Notice
Patient Preparation

Comments

Venostasis may cause up to 30% increase in 5 minutes.   

Haemolysis, prolonged standing of specimen and/or squeezing of heel or finger (adding tissue fluid to the sample) during paediatric collects with give elevated results.  

Owner Clair Crossley (Crossley1)
Last reviewed 23 Sep 2026
Next review 23 Sep 2027 OK