Tests:Alanine Amino Transferase, Plasma: Difference between revisions

From Taranaki Lab Manual
Tests:Alanine Amino Transferase, Plasma
Jump to navigation Jump to search
No edit summary
Updated method Alinity
 
(7 intermediate revisions by 3 users not shown)
Line 4: Line 4:


[[Category:Biochemistry]]  
[[Category:Biochemistry]]  
[[Category:Hawera]]


{| class="wikitable"
{| class="wikitable"
Line 34: Line 35:
== Specimen Requirements ==
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen  
|Plasma
|<span style="background:#3cb371"> Green </span> top Li-Hep tube (Plasma)
Serum
<span style="background:#e30022"> Red </span> or Yellow top tube (Serum)
|-
|-
|Preferred
|Unacceptable
|6 mL plain <span style="background:#e30022"> Red-Top </span>
|Moderately and Grossly Haemolysed samples
|-
|Accepted
|4.5 mL Lithium Heparin <span style="background:#3cb371"> Green-Top </span>
|-
|-
|Unacceptable
|Specimen Transportation
|Haemolysed
|
|-
|-
|Paediatric  Requirements
|Paediatric  Requirements
|600 µL <span style="background:#99e6b3"> Lithium Heparin Microtainer </span>  
|600 µL <span style="background:#99e6b3"> Li-Hep Microtainer </span>   
|-
! colspan="2" |
== Aliquot Requirements ==
|-
|Sample Type
|Plasma
Serum
|-
|Minimum Volume
|100 µL
|-
|-
|Aliquot Transportation
|Aliquot Transportation
Line 74: Line 62:
|Test Method
|Test Method


|Ci8200 analyser, Abbott Reagents. Based on IFCC recommendation.
|Abbott Alinity c series analyser using Abbott reagents.  
|-
|-
|Advanced Notice
|Advanced Notice
Line 89: Line 77:
|}
|}
__FORCETOC__
__FORCETOC__
{{DocMeta
| owner = Crossley1
| review_ping =
}}

Latest revision as of 21:24, 23 September 2026


Overview

Department Biochemistry
Test Code PALT
Synonyms ALT

SGPT

Alanine Aminotransferase

Availability Monday - Sunday, testing routinely available out of hours
Turnaround Time 1 – 2 hours
Stability – Add test     24 Hours

Specimen Requirements

Specimen Green top Li-Hep tube (Plasma)

Red or Yellow top tube (Serum)

Unacceptable Moderately and Grossly Haemolysed samples
Specimen Transportation
Paediatric Requirements 600 µL Li-Hep Microtainer    
Aliquot Transportation Chilled (2 - 8 degrees Celsius)

Clinical Information

Reference Intervals Male reference range 0 - 40 U/L

Female reference range 0 - 30 U/L  

Test Method Abbott Alinity c series analyser using Abbott reagents.
Advanced Notice Not required
Patient Preparation Not required

Comments

This test is more discriminating for liver pathology than AST.  
Owner Clair Crossley (Crossley1)
Last reviewed 23.09.2026
Next review 23.09.2027 (OK)