Tests:SARS-CoV-2: Difference between revisions
- Department
- Microbiology
- Also at
- Hawera
Tests:SARS-CoV-2
m Bulk update DocMeta owner to Williams1 |
m Mark as reviewed |
||
| (6 intermediate revisions by 3 users not shown) | |||
| Line 3: | Line 3: | ||
[[Category:Tests]] | [[Category:Tests]] | ||
[[Category:Microbiology]] | [[Category:Microbiology]] | ||
[[Category:Hawera]] | |||
{| class="wikitable" | {| class="wikitable" | ||
| Line 13: | Line 15: | ||
|- | |- | ||
|Test Code | |Test Code | ||
| | |RESP | ||
|- | |- | ||
|Synonyms | |Synonyms | ||
| Line 24: | Line 26: | ||
2019-nCov | 2019-nCov | ||
|- | |- | ||
|Availability | |Base Lab Availability | ||
|Monday - Friday, Testing routinely available out of hours | |Monday - Friday, Testing routinely available out of hours | ||
|- | |||
|Hawera Lab Availability | |||
|Monday - Friday, 8am to 4 30pm | |||
|- | |- | ||
|Turnaround Time | |Turnaround Time | ||
| Line 35: | Line 40: | ||
|- | |- | ||
|Stability – Add test | |Stability – Add test | ||
| | |Add-ons can be made if an appropriate sample has already been received for other PCR testing within one week of specimen collection. | ||
|- | |- | ||
! colspan="2" | | ! colspan="2" | | ||
| Line 77: | Line 82: | ||
|- | |- | ||
|Reference Intervals | |Reference Intervals | ||
|Results will be reported as Novel Coronavirus RNA PCR DETECTED or NOT Detected. | |Results will be reported as Novel Coronavirus RNA PCR DETECTED or NOT Detected. | ||
Specimens that fail for technical reasons will be tested by another platform or a repeat sample requested, this will mean a delay in results | |||
Specimens that fail for technical reasons will be tested by another platform or a repeat sample requested, this will mean a | |||
|- | |- | ||
|Test Method | |Test Method | ||
| Line 105: | Line 107: | ||
| review_ping = | | review_ping = | ||
}} | }} | ||
<!-- review-ping: 2026-11-17T23:52:57.254Z --> | |||
Latest revision as of 12:52, 18 November 2026
Overview | |
|---|---|
| Department | Microbiology – Molecular |
| Test Code | RESP |
| Synonyms | COVID-19
SARS-CoV-2 Novel Coronavirus 2019-nCov |
| Base Lab Availability | Monday - Friday, Testing routinely available out of hours |
| Hawera Lab Availability | Monday - Friday, 8am to 4 30pm |
| Turnaround Time | 2 – 24 hours from receipt
Results may be delayed out of routine business hours. Urgent requests will be prioritised |
| Stability – Add test | Add-ons can be made if an appropriate sample has already been received for other PCR testing within one week of specimen collection. |
Specimen Requirements | |
| Specimen | Swab |
| Preferred | Nasopharyngeal swab in VTM (Viral transport medium) |
| Acceptable | |
| Unacceptable | |
| Specimen Transportation | ASAP to Laboratory |
| Paediatric Requirements | Paediatric nasopharyngeal swab in VTM (Viral transport medium) |
Aliquot Requirements | |
| Sample | |
| Preferred Volume | |
| Minimum Volume | |
| Aliquot Transportation | If there is a delay in getting sample to the laboratory, please store sample chilled (2 - 8 degrees Celsius) |
Clinical Information | |
| Reference Intervals | Results will be reported as Novel Coronavirus RNA PCR DETECTED or NOT Detected.
Specimens that fail for technical reasons will be tested by another platform or a repeat sample requested, this will mean a delay in results |
| Test Method | Real-time RT-PCR test on the GeneXpert analyser for the qualitative detection of nucleic acid from the SARS-CoV-2 virus.
Note if a “QUAD” swab is requested then Influenza A + B, RSV, and SARS-CoV-2 are tested. |
| Advanced Notice | Not required |
| Patient Preparation | To minimise inhibition in the assay, please ensure the patients blow their nose prior to taking a nasopharyngeal swab. |
Comments | |
| Influenza A/B and RSV, Full Respiratory Multiplex and Bordetella pertussis PCR may be carried out on the same nasopharyngeal swab.
Please note: Testing of the full respiratory multiplex assay does not have the same turnaround time as the Influenza A/B, RSV test as the sample is forwarded to a reference laboratory. | |
| Owner | Melanie Williams (Williams1) |
|---|---|
| Last reviewed | 18 Nov 2026 |
| Next review | 18 Nov 2027 OK |