Tests:Alanine Amino Transferase, Plasma: Difference between revisions

From Taranaki Lab Manual
Tests:Alanine Amino Transferase, Plasma
Jump to navigation Jump to search
Created page with "{{DISPLAYTITLE: Alanine Amino Transferase, Plasma}} Full Test List Biochemistry Tests {| class="wikitable" ! colspan="2" |'''''Overview''''' |- |Department |Biochemistry |- |Test Code |PALT |- |Synonyms |ALT SGPT |- |Turnaround Time |1 – 2 hours |- |Stability – Add test     |24 Hours |- ! colspan="2" |'''''Specimen Requirements''''' |- |Specimen Type |Lithium heparin <span style="background:#3cb371"> green-top </span> |- |Preferred Volume |4.5ml |-..."
 
Updated method Alinity
 
(22 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{DISPLAYTITLE: Alanine Amino Transferase, Plasma}}   
{{DISPLAYTITLE: Alanine Amino Transferase, Plasma}}   
[[Category:Tests]]
[[Category:Tests]]
[[Category:Biochemistry]]  
[[Category:Biochemistry]]  
[[Category:Hawera]]


{| class="wikitable"
{| class="wikitable"
! colspan="2" |'''''Overview'''''
! colspan="2" |
== Overview ==
|-
|-
|Department
|Department
Line 16: Line 20:


SGPT
SGPT
Alanine Aminotransferase
|-
|Availability
|Monday - Sunday, testing routinely available out of hours
|-
|-
|Turnaround Time
|Turnaround Time
Line 23: Line 32:
|24 Hours
|24 Hours
|-
|-
! colspan="2" |'''''Specimen Requirements'''''
! colspan="2" |
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen  
|Lithium heparin <span style="background:#3cb371"> green-top </span>
|<span style="background:#3cb371"> Green </span> top Li-Hep tube (Plasma)
<span style="background:#e30022"> Red </span> or Yellow top tube (Serum)
|-
|-
|Preferred Volume
|Unacceptable
|4.5ml
|Moderately and Grossly Haemolysed samples
|-
|-
|Acceptable
|Specimen Transportation
|
|
|-
|-
|Pediatric Requirements
|Paediatric Requirements
|Heparin microtainer tube  600 µL  
|600 µL <span style="background:#99e6b3"> Li-Hep Microtainer </span>   
|-
! colspan="2" |'''''Aliquot Requirements'''''
|-
|Sample Type
|Plasma or serum
|-
|Minimum Volume
|100 µL
|-
|-
|Aliquot Transportation
|Aliquot Transportation
|Chilled (2 - 8 degrees  Celsius)
|Chilled (2 - 8 degrees  Celsius)
|-
|-
! colspan="2" |'''''Clinical Information'''''
! colspan="2" |
== Clinical Information ==
|-
|-
|Reference Intervals
|Reference Intervals
|Male reference range 0 -  40 U/L
|Male reference range 0 -  40 U/L


Line 56: Line 61:
|-
|-
|Test Method
|Test Method
|Ci8200 analyser, Abbott Reagents. Based on IFCC recommendation.
 
|Abbott Alinity c series analyser using Abbott reagents.  
|-
|-
|Advanced Notice
|Advanced Notice
|Not required
|-
|Patient Preparation
|Not required
|Not required
|-
|-
! colspan="2" |'''''Comments'''''
! colspan="2" |
== Comments ==
|-
|-
| colspan="2" |This test is more discriminating for liver pathology than AST.  
| colspan="2" |This test is more discriminating for liver pathology than AST.  
|}
|}
__FORCETOC__
__FORCETOC__
{{DocMeta
| owner = Crossley1
| review_ping =
}}

Latest revision as of 22:24, 23 September 2026


Overview

Department Biochemistry
Test Code PALT
Synonyms ALT

SGPT

Alanine Aminotransferase

Availability Monday - Sunday, testing routinely available out of hours
Turnaround Time 1 – 2 hours
Stability – Add test     24 Hours

Specimen Requirements

Specimen Green top Li-Hep tube (Plasma)

Red or Yellow top tube (Serum)

Unacceptable Moderately and Grossly Haemolysed samples
Specimen Transportation
Paediatric Requirements 600 µL Li-Hep Microtainer    
Aliquot Transportation Chilled (2 - 8 degrees Celsius)

Clinical Information

Reference Intervals Male reference range 0 - 40 U/L

Female reference range 0 - 30 U/L  

Test Method Abbott Alinity c series analyser using Abbott reagents.
Advanced Notice Not required
Patient Preparation Not required

Comments

This test is more discriminating for liver pathology than AST.  
Owner Clair Crossley (Crossley1)
Last reviewed 23.09.2026
Next review 23.09.2027 (OK)