Jump to content
Health NZ Taranaki Lab Manual

Tests:Thrombin Clotting Time, Plasma: Difference between revisions

Department
Haematology
Also at
Hawera
Tests:Thrombin Clotting Time, Plasma
Created page with "{{DISPLAYTITLE: Thrombin Clotting Time, Plasma}} Full Test List Haematology Tests {| class="wikitable" ! colspan="2" | == Overview == |- |Department |Haematology |- |Test Code | |- |Synonyms |TCT Thrombin Time |- |Turnaround Time |1-4 hrs |- |Stability – Add test |24 hrs |- ! colspan="2" | == Specimen Requirements == |- |Specimen Type |Plasma |- |Specimen Transportation | |- |Preferred |Full 2.7 mL Na citrate <span style="background: #87c..."
 
mNo edit summary
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
Thrombin clotting time is performed with a coagulation screen  
{{DISPLAYTITLE: Thrombin Clotting Time, Plasma}}   
{{DISPLAYTITLE: Thrombin Clotting Time, Plasma}}   


Line 4: Line 6:


[[Category:Haematology]]   
[[Category:Haematology]]   
[[Category:Hawera]] 
{| class="wikitable"
{| class="wikitable"
! colspan="2" |
! colspan="2" |
Line 12: Line 15:
|-
|-
|Test Code  
|Test Code  
|
|TTCT
CS
|-
|-
|Synonyms  
|Synonyms  
Line 18: Line 22:


Thrombin Time  
Thrombin Time  
|-
|Availability
|Monday - Sunday, testing routinely available out of hours
|-
|-
|Turnaround Time  
|Turnaround Time  
Line 28: Line 35:
== Specimen Requirements ==
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen  
|Plasma
|Plasma
|-
|Specimen Transportation
|
|-
|-
|Preferred  
|Preferred  
Line 40: Line 44:
|
|
|-
|-
|Pediatric Requirements    
|Unacceptable
|Clotted samples
Under or overfilled tubes
Grossly haemolysed
Samples older than 24 hours
|-
|Specimen Transportation
|
|-
|Paediatric Requirements    
|1 mL Na Citrate <span style="background: #87cefa "> Blue-Top </span>  
|1 mL Na Citrate <span style="background: #87cefa "> Blue-Top </span>  
|-
|-
Line 46: Line 59:
== Aliquot Requirements ==
== Aliquot Requirements ==
|-
|-
|Sample Type
|Sample  
|
|-
|Preferred Volume
|
|
|-
|-
Line 70: Line 86:
|-
|-
|Test Method  
|Test Method  
|Mechanical clot detection performed on Stago Compact Max2 Analyser  
|Mechanical clot detection performed on Stago Compact Max<sup>3</sup> Analyser  
|-
|-
|Advanced Notice  
|Advanced Notice  
Line 81: Line 97:
== Comments ==
== Comments ==
|-
|-
| colspan="2" |Thrombin clotting time is performed with a coagulation screen  
| colspan="2" |Protamine sulphate may be added to the TCT to exclude or indicate heparin contamination.


Protamine sulphate may be added to the TCT to exclude or indicate heparin contamination.
Any prolongation of the thrombin time may indicate the presence of a high level fibrin degradation products, 


Any prolongation of the thrombin time may indicate the presence of a high level fibrin degradation products, hypo- or afibrinogenemia, dysfibrinogenemia, the presence of Heparin, Dabigatran, or a high concentration of serum proteins.  
hypo- or afibrinogenemia, dysfibrinogenemia, the presence of Heparin, Dabigatran, or a high concentration of serum proteins.  
|}
|}
{{DocMeta
| owner = Mabbett1
| review_ping =
}}

Latest revision as of 16:41, 13 November 2026

Thrombin clotting time is performed with a coagulation screen  

Overview

Department Haematology
Test Code TTCT

CS

Synonyms TCT

Thrombin Time

Availability Monday - Sunday, testing routinely available out of hours
Turnaround Time 1-4 hrs
Stability – Add test 24 hrs

Specimen Requirements

Specimen Plasma
Preferred Full 2.7 mL Na citrate Blue-Top
Acceptable
Unacceptable Clotted samples

Under or overfilled tubes Grossly haemolysed Samples older than 24 hours

Specimen Transportation
Paediatric Requirements   1 mL Na Citrate Blue-Top

Aliquot Requirements

Sample
Preferred Volume
Minimum Volume
Aliquot Transportation

Clinical Information

Reference Intervals Reference Range: < 21 sec.

Interpretation of TCT and Protamine TCT:

TCT TCT + PrSo4 Interpretation

Prolonged Normal Consistent with Heparin

Prolonged Prolonged Consistent with Dabigatran, DIC, low fibrinogen.

Test Method Mechanical clot detection performed on Stago Compact Max3 Analyser
Advanced Notice Not required
Patient Preparation Not required

Comments

Protamine sulphate may be added to the TCT to exclude or indicate heparin contamination.

Any prolongation of the thrombin time may indicate the presence of a high level fibrin degradation products,

hypo- or afibrinogenemia, dysfibrinogenemia, the presence of Heparin, Dabigatran, or a high concentration of serum proteins.

Owner Craig Mabbett (Mabbett1)
Last reviewed 13 Nov 2026
Next review 13 Nov 2027 OK