Tests:Potassium, Plasma: Difference between revisions

From Taranaki Lab Manual
Tests:Potassium, Plasma
Jump to navigation Jump to search
No edit summary
No edit summary
 
(5 intermediate revisions by 3 users not shown)
Line 3: Line 3:
[[Category:Tests]]  
[[Category:Tests]]  


[[Category:Biochemistry]]
[[Category:Biochemistry]]
[[Category:Hawera]]
{| class="wikitable"
{| class="wikitable"
! colspan="2" |
! colspan="2" |
Line 23: Line 24:
Na & K    
Na & K    
|-
|-
|Test Availabilty
|Base Lab Availability
|Monday - Sunday, testing routinely available out of hours  
|Monday - Sunday, testing routinely available out of hours  
|-
|Hawera Lab Availability
|Monday - Friday, 8am to 4 30pm
|-
|-
|Turnaround Time  
|Turnaround Time  
Line 35: Line 39:
== Specimen Requirements ==
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen  
|Plasma
|Plasma


Line 58: Line 62:
== Aliquot Requirements ==
== Aliquot Requirements ==
|-
|-
|Sample Type
|Sample  
|
|
|-
|-
Line 77: Line 81:
|-
|-
|Test Method  
|Test Method  
|Ion selective electrode (Indirect method) performed on the Abbott ci8200 analyser  
|Abbott Alinity c series analyser using Abbott reagents.  Indirect by Ion Selective Electrode.
|-
|-
|Advanced Notice  
|Advanced Notice  
Line 92: Line 96:
Haemolysis, prolonged standing of specimen and/or squeezing of heel or finger (adding tissue fluid to the sample) during paediatric collects with give elevated results.    
Haemolysis, prolonged standing of specimen and/or squeezing of heel or finger (adding tissue fluid to the sample) during paediatric collects with give elevated results.    
|}
|}
{{DocMeta
| owner = Crossley1
| review_ping =
}}

Latest revision as of 20:59, 23 September 2026

Overview

Department Biochemistry  
Test Code PPOT
Constituent Tests Anion Gap

Electrolytes

Synonyms Electrolytes (includes Na)  

Na & K  

Base Lab Availability Monday - Sunday, testing routinely available out of hours
Hawera Lab Availability Monday - Friday, 8am to 4 30pm
Turnaround Time 1 – 4hrs  
Stability – Add test 3 hrs

Specimen Requirements

Specimen Plasma

Serum

Preferred 6 mL Plain Red-Top
Acceptable 4 mL Li-Heparin Green-Top    
Unacceptable Moderately and grossly haemolysed samples
Specimen Transportation
Paediatric Requirements   600 µL Li-Hep Microtainer   

Aliquot Requirements

Sample
Preferred Volume
Minimum Volume
Aliquot Transportation

Clinical Information

Reference Intervals All ages: 3.5 - 5.2 mmol/L  
Test Method Abbott Alinity c series analyser using Abbott reagents.  Indirect by Ion Selective Electrode.
Advanced Notice
Patient Preparation

Comments

Venostasis may cause up to 30% increase in 5 minutes.   

Haemolysis, prolonged standing of specimen and/or squeezing of heel or finger (adding tissue fluid to the sample) during paediatric collects with give elevated results.  

Owner Clair Crossley (Crossley1)
Last reviewed 23.09.2026
Next review 23.09.2027 (OK)