Jump to content
Health NZ Taranaki Lab Manual

Tests:INR, Plasma: Difference between revisions

Department
Haematology
Also at
Hawera
Tests:INR, Plasma
Created page with "Part of the Coagulation screen {{DISPLAYTITLE: INR, Plasma}} Full Test List Haematology Tests Hawera Tests {| class="wikitable" ! colspan="2" | == Overview == |- |Department |Haematology     |- |Test Code |INR |- |Synonyms |Prothrombin time   INR   International Normalised Ratio   |- |Availability |Monday - Sunday, testing routinely available out of hours |- |Turnaround Time |0.5 – 4 hrs   |- |Stability – Add test |24 hrs |- ! cols..."
 
No edit summary
Line 24: Line 24:
International Normalised Ratio    
International Normalised Ratio    
|-
|-
|Availability
|Base Lab Availability
|Monday - Sunday, testing routinely available out of hours  
|Monday - Sunday, testing routinely available out of hours  
|-
|Hawera Lab Availability
|Monday - Friday, 8am to 4 30pm
|-
|-
|Turnaround Time
|Turnaround Time

Revision as of 09:41, 3 October 2025

Part of the Coagulation screen

Overview

Department Haematology    
Test Code INR
Synonyms Prothrombin time  

INR  

International Normalised Ratio  

Base Lab Availability Monday - Sunday, testing routinely available out of hours
Hawera Lab Availability Monday - Friday, 8am to 4 30pm
Turnaround Time 0.5 – 4 hrs  
Stability – Add test 24 hrs

Specimen Requirements

Specimen Plasma
Preferred Full 2.7 mL Blue-Top Na citrate tube    
Acceptable
Unacceptable Clotted sample

Over or underfilled samples Grossly haemolysed Samples older than 4 hours

Specimen Transportation
Paediatric Requirements   1 mL Blue-Top Na citrate tube

Aliquot Requirements

Sample
Preferred Volume
Minimum Volume
Aliquot Transportation

Clinical Information

Reference Intervals Prothrombin Ratio Reference Range:  

0.8-1.2  


INR Therapeutic Range: (Warfarin Therapy)   

2.0 - 2.5 Prophylaxis of Deep Vein Thrombosis   

2.0 - 3.0 Current active management of DVT and Pulmonary embolism   

3.0 - 4.0 Prosthetic heart valves and grafts  

 

Test Method Mechanical clot detection performed on Stago Compact Max2 Analyser  
Advanced Notice Not required    
Patient Preparation Not required    

Comments

Please request INR if patient is on oral warfarin anticoagulation so the correct report format and reference range is applied.  
Owner Craig Mabbett (Mabbett1)
Last reviewed 3 Oct 2025
Next review Overdue, 3 Oct 2026