Revision as of 15:43, 18 March 2025


Overview

Department Biochemistry
Test Code PALT
Synonyms ALT

SGPT

Alanine Aminotransferase

Availability Monday - Sunday, testing routinely available out of hours
Turnaround Time 1 – 2 hours
Stability – Add test     24 Hours

Specimen Requirements

Specimen Plasma

Serum

Preferred 6 mL plain Red-Top
Accepted 4.5 mL Li-Hep Green-Top
Unacceptable Haemolysed
Specimen Transportation
Paediatric Requirements 600 µL Li-Hep Microtainer    

Aliquot Requirements

Sample Plasma

Serum

Preferred Volume
Minimum Volume 100 µL
Aliquot Transportation Chilled (2 - 8 degrees Celsius)

Clinical Information

Reference Intervals Male reference range 0 - 40 U/L

Female reference range 0 - 30 U/L  

Test Method Ci8200 analyser, Abbott Reagents. Based on IFCC recommendation.
Advanced Notice Not required
Patient Preparation Not required

Comments

This test is more discriminating for liver pathology than AST.