Tests:INR, Plasma
No edit summary |
Updated sample requirements and comments |
||
| Line 18: | Line 18: | ||
|- | |- | ||
|Synonyms | |Synonyms | ||
|Prothrombin | |Prothrombin Ratio | ||
INR | INR | ||
| Line 51: | Line 51: | ||
|Clotted sample | |Clotted sample | ||
Over or underfilled samples | Over or underfilled samples | ||
Grossly | |||
Samples | Grossly Haemolysed | ||
Samples >24 hours old | |||
Refrigerated samples (<8°C) | |||
|- | |- | ||
|Specimen Transportation | |Specimen Transportation | ||
| Line 95: | Line 99: | ||
|- | |- | ||
|Test Method | |Test Method | ||
|Mechanical clot detection performed on Stago Compact | |Mechanical clot detection performed on Stago Compact Max³ Analyser | ||
|- | |- | ||
|Advanced Notice | |Advanced Notice | ||
| Line 106: | Line 110: | ||
== Comments == | == Comments == | ||
|- | |- | ||
| colspan="2" |Please request | | colspan="2" |Please indicate on the request form if the patient is prescribed anticoagulants. | ||
|} | |} | ||
{{DocMeta | {{DocMeta | ||
Latest revision as of 15:58, 3 October 2026
Part of the Coagulation screen
Overview | |
|---|---|
| Department | Haematology |
| Test Code | INR |
| Synonyms | Prothrombin Ratio
INR International Normalised Ratio |
| Base Lab Availability | Monday - Sunday, testing routinely available out of hours |
| Hawera Lab Availability | Monday - Friday, 8am to 4 30pm |
| Turnaround Time | 0.5 – 4 hrs |
| Stability – Add test | 24 hrs |
Specimen Requirements | |
| Specimen | Plasma |
| Preferred | Full 2.7 mL Blue-Top Na citrate tube |
| Acceptable | |
| Unacceptable | Clotted sample
Over or underfilled samples Grossly Haemolysed Samples >24 hours old Refrigerated samples (<8°C) |
| Specimen Transportation | |
| Paediatric Requirements | 1 mL Blue-Top Na citrate tube |
Aliquot Requirements | |
| Sample | |
| Preferred Volume | |
| Minimum Volume | |
| Aliquot Transportation | |
Clinical Information | |
| Reference Intervals | Prothrombin Ratio Reference Range:
0.8-1.2
2.0 - 2.5 Prophylaxis of Deep Vein Thrombosis 2.0 - 3.0 Current active management of DVT and Pulmonary embolism 3.0 - 4.0 Prosthetic heart valves and grafts
|
| Test Method | Mechanical clot detection performed on Stago Compact Max³ Analyser |
| Advanced Notice | Not required |
| Patient Preparation | Not required |
Comments | |
| Please indicate on the request form if the patient is prescribed anticoagulants. | |
| Owner | Craig Mabbett (Mabbett1) |
|---|---|
| Last reviewed | 3 Oct 2026 |