Jump to content
Health NZ Taranaki Lab Manual

Tests:D Dimer Assay, Plasma: Difference between revisions

Department
Haematology
Also at
Hawera
Tests:D Dimer Assay, Plasma
hopefully fixed RI table
Tags: Reverted Visual edit
m Reverted edits by Mabbett1 (talk) to last revision by Kasey Ali Glennie (Kgl005)
Tag: Rollback
Line 49: Line 49:
|Clotted sample
|Clotted sample
Under or overfilled tubes
Under or overfilled tubes
 
Haemolysed
Haemolysed  
Sample older than 24 hours
 
Sample >24 hours old
|-
|-
|Specimen Transportation  
|Specimen Transportation  
Line 79: Line 77:
|-
|-
|Reference Intervals  
|Reference Intervals  
|{| class="wikitable"
|Reference range:  <500 µg/L  
|+
!Age
!Cut-off
!Comment
|-
|≤ 50 years
|<500 µg/L
|Less than or equal to 50 years old.
In this age group one third of patients without VTE will have a positive D-dimer result.
|-
|51-60 years
|<600 µg/L
|51-60 years old.
In this age group nearly half of patients without VTE will have a positive D-dimer result.
|-
|61-70 years
|<700 µg/L
|61-70 years old.
In this age group half of patients without VTE will have a positive D-dimer result.
|-
|71-80 years
|<800 µg/L
|71-80 years old.
In this age group more than half of patients without VTE will have a positive D-dimer result.
|-
|>80 years
|<900 µg/L
|>80 years old.
In this age group two thirds of patients without VTE will have a positive D-dimer result.
|}
|-
|-
|Test Method  
|Test Method  
|Turbidometric immunoassay performed on Stago Compact Max³ Analyser  
|Turbidometric immunoassay performed on Stago Compact Max2 Analyser  
|-
|-
|Advanced Notice  
|Advanced Notice  
Line 123: Line 91:
== Comments ==
== Comments ==
|-
|-
| colspan="2" |Clinical Reminder: The D-dimer test is only useful for exclusion of VTE in patients with a low clinical probability of DVT or PE.  
| colspan="2" |Clinical Reminder: The D-Dimer test is only useful for exclusion of VTE in patients with a low clinical probability of DVT or PE.  


A negative result largely excludes VTE in this setting, while a positive result is non-specific    
A negative result largely excludes VTE in this setting, while a positive result is non-specific    

Revision as of 16:08, 4 October 2026

Overview

Department Haematology    
Test Code DIME
Synonyms XDP  

FDP  

Part of DIC Screen

Base Lab Availability Monday - Sunday, testing routinely available out of hours
Hawera Lab Availability Monday- Friday, 8am to 4 30pm
Turnaround Time 2 hours    
Stability – Add test 24 hours

Specimen Requirements

Specimen Plasma
Preferred 2.7 mL Sodium Citrate Blue-Top
Acceptable
Unacceptable Clotted sample

Under or overfilled tubes Haemolysed Sample older than 24 hours

Specimen Transportation
Paediatric Requirements   1 mL Sodium Citrate Blue-Top  

Aliquot Requirements

Sample
Preferred Volume
Minimum Volume
Aliquot Transportation

Clinical Information

Reference Intervals Reference range:  <500 µg/L  
Test Method Turbidometric immunoassay performed on Stago Compact Max2 Analyser
Advanced Notice Not required    
Patient Preparation Not required    

Comments

Clinical Reminder: The D-Dimer test is only useful for exclusion of VTE in patients with a low clinical probability of DVT or PE.

A negative result largely excludes VTE in this setting, while a positive result is non-specific  

Owner Craig Mabbett (Mabbett1)
Last reviewed 4 Oct 2026
Next review 4 Oct 2027 OK