Tests:Ammonia, Blood: Difference between revisions

From Taranaki Lab Manual
Tests:Ammonia, Blood
Jump to navigation Jump to search
No edit summary
No edit summary
Line 5: Line 5:
{| class="wikitable"
{| class="wikitable"
! colspan="2" |
! colspan="2" |
===''Overview''===
==Overview==
|-
|-
|Department
|Department
|Biochemistry
|Biochemistry
|-
|-
|Test Code
|Test Code  
|WAMM
|WAMM
|-
|-
|Synonyms
|Synonyms
|NH3 
|NH3 
|-
|Test Availability
|Monday - Sunday, testing routinely available out of hours
|-
|-
|Turnaround Time
|Turnaround Time
Line 20: Line 23:
|-
|-
|Stability – Add test
|Stability – Add test
|Cannot be added on.
|Cannot be added on
|-
|-
! colspan="2" |
! colspan="2" |
===''Specimen Requirements''===
==Specimen Requirements==
|-
|-
|Specimen Type
|Specimen Type
|Plasma
|Plasma
|-
|Specimen Transportation
|On ice, sample must be received at lab within 15 minutes of collection.      
|-
|-
|Preferrred
|Preferrred
|4 mL EDTA (K2E) <span style="background: #ba55d3"> Purple-Top </span> on ice.
|4 mL EDTA (K2E) <span style="background: #ba55d3"> Purple-Top </span>
|-
|-
|Acceptable
|Acceptable
|
|
|-
|-
|Specimen Transportation
|Unacceptable
|On ice. Sample must be received at lab within 15 minutes of collection.      
|Sample not received on ice
Capillary blood
Highly icteric samples
Moderate haemolysis
|-
|-
|Pediatric Requirements
|Paediatric Requirements
| 600uL EDTA (K2E) <span style="background: #ffc0cb"> Pink-Top </span> Microtainer on ice. 
|600uL <span style="background: #dcd0ff"> EDTA Microtainer </span>
|-
|-
! colspan="2" |
! colspan="2" |
===''Aliquot Requirements''===
==Aliquot Requirements==
|-
|-
|Sample Type
|Sample Type
Line 53: Line 62:
|-
|-
! colspan="2" |
! colspan="2" |
===''Clinical Information''===
==Clinical Information==
|-
|-
|Reference Intervals
|Reference Intervals
|FEMALE: 11-51 umol/L  
|Female: 11-51 umol/L  
MALE 16-60 umol/L   
Male: 16-60 umol/L   
|-
|-
|Test Method
|Test Method
Line 63: Line 72:
|-
|-
|Advanced Notice
|Advanced Notice
|Please notify Biochemistry extension 7881  
|Please notify Biochemistry extension 7881    
|-
|-
|Patient Preparation  
|Patient Preparation    
|Ideally patient fasted >6 hours.  
|Ideally patient fasted >6 hours.  
No fist clenching. 
No fist clenching. 
|-
|-
! colspan="2" |
! colspan="2" |  
===''Comments''===
==Comments==
|-
|-
| colspan="2" |Specimen must be centrifuged at 4°C IMMEDIATELY after  receipt.   
| colspan="2" |Specimen must be centrifuged at 4°C IMMEDIATELY after  receipt.   
Line 76: Line 85:
False high values are obtained after muscular exercise.   
False high values are obtained after muscular exercise.   


Please notify the laboratory if patient is on Sulfasalazine/Sulfapyridine  medications as these may interfere with this method
Please notify the laboratory if patient is on Sulfasalazine/Sulfapyridine  medications as these may interfere with this method  
|}
|}

Revision as of 16:13, 11 March 2025


Overview

Department Biochemistry
Test Code WAMM
Synonyms NH3 
Test Availability Monday - Sunday, testing routinely available out of hours
Turnaround Time 3 hours
Stability – Add test Cannot be added on

Specimen Requirements

Specimen Type Plasma
Specimen Transportation On ice, sample must be received at lab within 15 minutes of collection.      
Preferrred 4 mL EDTA (K2E) Purple-Top
Acceptable
Unacceptable Sample not received on ice

Capillary blood Highly icteric samples Moderate haemolysis

Paediatric Requirements 600uL EDTA Microtainer

Aliquot Requirements

Sample Type Plasma
Minimum Volume 200 uL 
Aliquot Transportation Frozen 

Clinical Information

Reference Intervals Female: 11-51 umol/L

Male: 16-60 umol/L   

Test Method Abbott Alinity C. Enzymatic method. 
Advanced Notice Please notify Biochemistry extension 7881  
Patient Preparation   Ideally patient fasted >6 hours.

No fist clenching. 

Comments

Specimen must be centrifuged at 4°C IMMEDIATELY after receipt. 

False high values are obtained after muscular exercise.

Please notify the laboratory if patient is on Sulfasalazine/Sulfapyridine medications as these may interfere with this method