Jump to content
Health NZ Taranaki Lab Manual

Tests:Fibrinogen, Plasma: Difference between revisions

Department
Haematology
Tests:Fibrinogen, Plasma
Created page with "{{DISPLAYTITLE: Fibrinogen, Plasma}} Full Test List Haematology Tests {| class="wikitable" ! colspan="2" | ===''Overview''=== |- |Department |Haematology     |- |Test Code |FIB |- |Synonyms |Coag screen DIC screen   |- |Turnaround Time |1 – 4 hrs     |- |Stability – Add test   |24 hrs |- ! colspan="2" | ===''Specimen Requirements''=== |- |Specimen Type | |- |Specimen Transportation |Ambient   |- |Preferred |2.7 mL na citrate <span style="back..."
 
No edit summary
Line 6: Line 6:
{| class="wikitable"
{| class="wikitable"
! colspan="2" |
! colspan="2" |
===''Overview''===
== Overview ==
|-
|-
|Department
|Department
Line 25: Line 25:
|-
|-
! colspan="2" |
! colspan="2" |
===''Specimen Requirements''===
== Specimen Requirements ==
|-
|-
|Specimen Type
|Specimen Type
|
|Plasma
|-
|Specimen Transportation
|Ambient  
|-
|-
|Preferred
|Preferred
Line 40: Line 37:
|-
|-
|Unacceptable
|Unacceptable
|
|Clotted samples
Under or overfilled tubes
Haemolysed
Samples older than 24 hours
|-
|Specimen Transportation
|Ambient  
|-
|-
|Paediatric Requirements  
|Paediatric Requirements  
Line 46: Line 49:
|-
|-
! colspan="2" |
! colspan="2" |
===''Aliquot Requirements''===
== Aliquot Requirements ==
|-
|-
|Sample Type
|Sample Type
|
|-
|Preferred Volume
|
|
|-
|-
Line 58: Line 64:
|-
|-
! colspan="2" |
! colspan="2" |
===''Clinical Information''===
== Clinical Information ==
|-
|-
|Reference Intervals
|Reference Intervals
Line 73: Line 79:
|-
|-
! colspan="2" |
! colspan="2" |
===''Comments''===
== Comments ==
|-
|-
| colspan="2" |Included in coagulation screen.  
| colspan="2" |Included in coagulation screen.  

Revision as of 15:38, 14 March 2025

Overview

Department Haematology    
Test Code FIB
Synonyms Coag screen

DIC screen  

Turnaround Time 1 – 4 hrs    
Stability – Add test   24 hrs

Specimen Requirements

Specimen Type Plasma
Preferred 2.7 mL na citrate Blue-Top
Acceptable
Unacceptable Clotted samples

Under or overfilled tubes Haemolysed Samples older than 24 hours

Specimen Transportation Ambient  
Paediatric Requirements   1.0 mL Blue-Top    

Aliquot Requirements

Sample Type
Preferred Volume
Minimum Volume
Aliquot Transportation

Clinical Information

Reference Intervals Reference Range  1.5 - 4.0 g/L  
Test Method Von Clauss method using mechanical clot detection, performed on Stago Compact Max2 Analyser  
Advanced Notice Not required    
Patient Preparation Not required    

Comments

Included in coagulation screen.  

Cryoprecipitate transfusion is indicated if fibrinogen is <1.0 g/L in the presence of clinical bleeding.