Tests:Lactate Dehydrogenase, Serum: Difference between revisions

From Taranaki Lab Manual
Tests:Lactate Dehydrogenase, Serum
Jump to navigation Jump to search
Created page with "{{DISPLAYTITLE: Lactate Dehydrogenase}} Full Test List Biochemistry Tests {| class="wikitable" ! colspan="2" | ===''Overview''=== |- |Department |Biochemistry  |- |Test Code |PLD |- |Synonyms |LD LDH  |- |Turnaround Time |1 – 3 hours  |- |Stability – Add test |4 hours |- ! colspan="2" | ===''Specimen Requirements''=== |- |Specimen Type |Plasma Serum |- |Specimen Transportation | |- |Preferred |6 mL Plain <span style="background:#e30022"> Red-Top</..."
 
No edit summary
Line 1: Line 1:
{{DISPLAYTITLE: Lactate Dehydrogenase}}  
{{DISPLAYTITLE: Lactate Dehydrogenase, Serum}}  
[[Category:Tests]]
[[Category:Tests]]
[[Category:Biochemistry]]  
[[Category:Biochemistry]]  

Revision as of 10:14, 17 March 2025

Overview

Department Biochemistry 
Test Code PLD
Synonyms LD

LDH 

Turnaround Time 1 – 3 hours 
Stability – Add test 4 hours

Specimen Requirements

Specimen Type Plasma

Serum

Specimen Transportation
Preferred 6 mL Plain Red-Top
Acceptable 4 mL Li-Heparin Green-Top
Paediatric Requirements  600 µL  Li-Hep Microtainer

Aliquot Requirements

Sample Type Plasma

Serum 

Minimum Volume 100 µL
Aliquot Transportation

Clinical Information

Reference Intervals
Age range Reference Interval
0 -14 days 310 – 1220 U/L
> 14 day – 1 year 190 – 450 U/L
> 1 year – 10 years 190 – 320 U/L
> 10 years – 15 years 160 – 280 U/L
> 15 years – 18 years 130 – 250 U/L
> 18 years 110 – 220 U/L
Test Method NADH consumption monitored at 340nm. Abbott Ci8200 analyser
Advanced Notice Not required 
Patient Preparation

Comments