Jump to content
Health NZ Taranaki Lab Manual

Blood Gas Analysis (POCT)

Department
Point of care
Revision as of 17:04, 1 October 2025 by Pam Chung (talk | contribs)

Tests:Blood gas Analysis (POCT)

Overview

Department Point of Care (POCT)
Test Code N/A
Synonyms BGAS, ABG, VBG 
Availability The analysers are available at both Taranaki Base and Hawera Hospital at various locations - Base ED, Theatres, ICU, NNU and Hawera ED
Turnaround Time Results within 1 minute from sampling on the analyser
Stability – Add test Sample must be processed within 30 minutes of collection. 

Specimen Requirements

Specimen whole blood
Preferred 1 mL in a Radiometer safePICO syringe or a full 45μL Radiometer safeCLINITUBES Capillary
Acceptable 0.5 mL in a heparinised syringe
Unacceptable Clotted samples

Samples with with large air gaps

Minimum Volume 0.2 mL whole blood in a 1 mL syringe  
Specimen Transportation ASAP from patient collection to analyser. Delays can compromise sample integrity and provide inaccurate results
Paediatric Requirements A full 45μL collected in a Radiometer safeCLINITUBES Capillary (short) or a full 100μL whole blood collect in Laboratory provided capillary tube (long). 

0.2 mL whole blood in a 1 mL syringe

Test Information

Test Method Radiometer ABL90 FLEX PLUS blood gas analyser 
Units of Measurement
Reference Intervals
Uncertainty of Measurement
Additional Information Blood gas panel includes:  pH, pCO2, pO2, HCO3, Base Excess, Hb, sO2, Na, K, ICa, Cl, Anion Gap, Glucose, Lactate, Carboxyhaemoglobin and Methaemoglobin.

Comments

Quick user guides for running samples are available near the analysers.

All procedures and competency checklist for sign-off are available on the intranet for all Health NZ staff. This test is covered under the current IANZ Laboratory accreditation.

Owner Pam Chung (Pchung)
Last reviewed 1 Oct 2025
Next review Overdue, 1 Oct 2026